Performance of a Kinetic-Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers

  1. M. Malnou,
  2. J. Aumentado,
  3. M. R. Vissers,
  4. J. D. Wheeler,
  5. J. Hubmayr,
  6. J. N. Ullom,
  7. and J. Gao
Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable
noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic-inductance traveling-wave parametric amplifier (KI-TWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise TΣ=6.3±0.5 K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the KI-TWPA’s performance limited by the temperature of its inputs, and by an excess of noise Tex=1.9 K. The dissipation of the KI-TWPA’s rf pump constitutes the main power load at 4 K and is about one percent that of a HEMT. These combined noise and power dissipation values pave the way for the KI-TWPA’s use as a replacement for semiconductor amplifiers.

Sub-Kelvin Thermometer for On-Chip Measurements of Microwave Devices Utilizing Two-Level Systems in Superconducting Microresonators

  1. J. Wheeler,
  2. M. R. Vissers,
  3. M. Malnou,
  4. J. Hubmayr,
  5. J. N. Ullom,
  6. and J. Gao
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range
is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~μK/Hz−−−√) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS thermometers to investigate static and transient chip heating in a kinetic inductance traveling-wave parametric amplifier operated with a strong pump tone. TLS thermometry may find broad application in cryogenic microwave devices such as superconducting qubits and detectors.

A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance

  1. M. Malnou,
  2. M. R. Vissers,
  3. J. D. Wheeler,
  4. J. Aumentado,
  5. J. Hubmayr,
  6. J. N. Ullom,
  7. and J. Gao
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot noise
thermometer, approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone compared to conventional four-wave mixing KIT devices. It is built in an artificial transmission line intrinsically matched to 50 Ohms, whose dispersion allows for a controlled amplification bandwidth. We experimentally measure 17.6+1.1−1.4 dB of gain across a 2 GHz bandwidth, with an input 1 dB compression power of -63 dBm within that bandwidth, in qualitative agreement with theory. Using the KIT as the first amplifier in an amplification chain, we measure a system-added noise of 0.61±0.08 K between 3.5 and 5.5 GHz, about one eighth the noise obtained when using only a representative classical amplifier. The KIT contribution to this added noise is estimated to be 0.2±0.1 K, consistent with the quantum limit on amplifier added noise. This device is therefore suitable to read large arrays of microwave kinetic inductance detectors or thousands of superconducting qubits.

Optimal operation of a Josephson parametric amplifier for vacuum squeezing

  1. M. Malnou,
  2. D. A. Palken,
  3. Leila R. Vale,
  4. Gene C. Hilton,
  5. and K. W. Lehnert
A Josephson parametric amplifier (JPA) can create squeezed states of microwave light, lowering the noise associated with certain quantum measurements. We experimentally study how the
JPA’s pump influences the phase-sensitive amplification and deamplification of a coherent tone’s amplitude when that amplitude is commensurate with vacuum fluctuations. We predict and demonstrate that by operating the JPA with a pump power greater than the value that maximizes gain, the amplifier distortion is reduced and consequently squeezing is improved. Optimizing the JPA’s operation in this fashion, we directly observe 3.87±0.03 dB of vacuum squeezing.